1.列出主機的storage資訊
命令:esxcli storage nmp device list
mpx.vmhba1:c0:t1:l0
device display name: local vmware, disk (mpx.vmhba1:c0:t1:l0)
storage array type: vmw_satp_local
storage array type device config: satp vmw_satp_local does not support device configuration.
path selection policy: vmw_psp_fixed
path selection policy device config:
path selection policy device custom config:
working paths: vmhba1:c0:t1:l0
is local sas device: false
is usb: false
is boot usb device: false
2. 請記下與裝置關聯的satp (storage array type: vmw_satp_local)
3. 新增psa宣告規則將裝置標記為ssd。
命令:esxcli storage nmp satp rule add -s vmw_satp_local --device mpx.vmhba1:c0:t1:l0 --option="enable_ssd"
4. **裝置,重新應用規則。
命令:esxcli storage core claimrule load
esxcli storage core claimrule run
esxcli storage core claiming reclaim --device mpx.vmhba1:c0:t1:l0
5.驗證裝置是否已標記為ssd (is ssd:true)
命令:esxcli storage core device list -d mpx.vmhba1:c0:t1:l0 | grep ssd